Generator Anti

Generator Anti-Vibration Mounts: Selection, Installation and Service

The anti-vibration mount is a small component with a large influence on the reliability of a diesel generator set. Every diesel engine produces vibration: the reciprocating forces of the pistons, the firing pulses of the cylinders, and the residual imbalance of the rotating parts generate forces that are transmitted to the base frame, the canopy, the radiators, the pipework, and the surrounding building. The anti-vibration mount, also called the rubber mount, the vibration isolator, or the engine mount, is the elastic element between the engine and the frame that absorbs this vibration and prevents it from being transmitted. This guide covers the construction and the types of the generator anti-vibration mounts, the natural frequency and the isolation principles, the selection, the installation, the inspection, the replacement, and the applications on the common engine families including the Chinese 6105, 4100, 4105, 6113, and 6126 series.

Vibration in a generator set is unavoidable, but it can be managed. The engine is mounted on a number of isolators, typically four to eight depending on the engine size, and the isolators are designed so that the natural frequency of the engine on its mounts is well below the excitation frequency of the engine. The result is that the isolators act as a filter: the vibration energy above the natural frequency is reduced by the elastic deflection of the rubber, and only a small fraction reaches the frame and the building.

What Is an Anti-Vibration Mount and Why Is It Required?

An anti-vibration mount is a flexible element that supports the weight of the engine or the generator set and isolates the vibration of the machine from the supporting structure. It consists of a rubber block or a rubber-metal element that is compressed or sheared by the weight of the engine, and the rubber absorbs the dynamic forces by deflecting. The mount is fitted between the engine feet and the base frame, or between the complete set and the floor or the anti-vibration raft.

The requirement for the mounts is set by the effect of the vibration on the equipment and the building. An engine bolted directly to a steel frame transmits the vibration to the frame, and the frame radiates the structure-borne noise into the room. The pipework and the electrical connections that are attached to the engine and the frame are fatigued by the vibration, and the instruments, the controls, and the surrounding equipment are affected. In a residential or a commercial building, the transmitted vibration and the noise are a cause of complaint, and the building structure can be excited at its own resonance.

The mounts also protect the engine and the alternator: by allowing a small elastic movement, they reduce the stress in the mounting points and the welds, and they accommodate the thermal expansion and the torque reaction of the engine under load. The correct mounts are therefore a reliability component as well as a comfort component. The installation guide covers the mounting of the set, and the engine mount guide covers the related mounting hardware.

How Vibration Isolation Works

Vibration isolation works on the principle of the natural frequency. The engine and the mounts form a spring-mass system: the mass of the engine is supported by the elastic stiffness of the mounts, and the system has a natural frequency, in hertz, that depends on the mass and the stiffness. When the engine runs, the excitation frequencies are the firing frequency and its harmonics, and the isolation is effective only when the excitation frequency is significantly higher than the natural frequency of the mount system.

The transmissibility of the system is the ratio of the force transmitted to the force generated. Below the natural frequency, the transmissibility is close to one, and the vibration is passed directly. At the natural frequency, the transmissibility rises sharply and the vibration is amplified, which is why the engine must never run at a speed that excites the resonance of the mount system. Above the natural frequency, the transmissibility falls, and the isolation increases as the frequency ratio rises. The rule of thumb for a good isolation is a frequency ratio of at least 2.5 to 3, which gives a transmissibility of roughly 10 to 20%, i.e. an isolation efficiency of 80 to 90%.

The natural frequency of the mount system is determined by the static deflection of the mounts under the weight of the engine: the greater the static deflection, the lower the natural frequency and the better the isolation at the running speed. A typical natural frequency for a generator set is 8 to 15 Hz, and the static deflection is in the range of 2 to 6 mm. The deflection is set by the mount design, the rubber hardness, and the number of the mounts. The maintenance schedule guide covers the checks of the mount condition, and the fan clutch guide covers the rotating components whose balance affects the vibration level.

Types of Generator Anti-Vibration Mounts

The mounts used on generator sets are classified by the loading mode and the construction:

Mount Type Loading Mode Typical Application Notes
Compression mount Rubber in compression Small and medium engines High load capacity, moderate isolation
Shear mount Rubber in shear Medium engines, close-coupled sets Soft, good isolation, lower load capacity
Compression-shear mount Combined loading Large engines and alternators Balanced stiffness, compact
Sandwich or plate mount Combined loading Generator sets and pumps Simple bolting, multiple sizes
Air spring Compressed air Very low frequency isolation For sensitive buildings, active levelling

The compression mount is the most common on the generator engines, because it carries the static weight with a small deflection and a compact size. The shear mount is used where a softer system is needed, but it has a lower load capacity and a larger size for the same load. The compression-shear mount is the standard for the larger sets, where both the vertical and the lateral forces must be isolated. The air spring is used only for the most sensitive installations, such as the studios and the laboratories, and it is rare in the standard generator market.

The rubber material is a natural or a synthetic rubber compound, selected for the load, the temperature, and the oil resistance. The natural rubber has the best fatigue life but a limited temperature and oil resistance; the chloroprene and the nitrile compounds are used where the oil and the temperature are higher. The rubber is bonded to the steel plates in the bonded mounts, and the bond quality is the critical manufacturing parameter, because a bond failure releases the engine. The oil seal kit guide covers the rubber compounds used in the sealing components, and the radiator guide covers the cooling package that is also isolated from the frame.

Selecting the Correct Mount

The selection of the mount is made from the static load, the excitation frequency, and the required isolation. The static load on each mount is the total weight of the engine and the driven equipment divided by the number of the mounts, with the distribution adjusted for the centre of gravity. The excitation frequency is the firing frequency of the engine at the normal running speed: for a four-stroke engine, the firing frequency in hertz is the speed in rpm divided by 60 and multiplied by half the number of the cylinders.

The required isolation at the running speed is set by the target transmissibility. The mount manufacturer provides the load-deflection curve and the natural frequency for each mount, and the buyer selects the mount whose natural frequency at the applied load gives a frequency ratio of at least 2.5. The mount must also carry the torque reaction of the engine and the lateral forces of the belt drives, and it must be checked for the deflection limit and the stability under the maximum torque.

The mounts are selected as a set, not individually, because the engine must be supported at the correct height and the four-corner loading must be balanced. The height of the mount is critical: a set of mounts with the same stiffness but different heights distorts the engine frame and overloads the higher mounts. The shim plates are used to level the set during the installation, and the mounts are torqued evenly. The typical selection parameters for the common engines are listed below:

Engine Family Approx. Set Weight (kg) Typical Mounts Natural Frequency (Hz)
4100 / 4102 series 350-500 4 compression-shear 10-14
4105 series 450-650 4-6 compression-shear 9-13
6105 series 700-1000 6-8 compression-shear 8-12
6113 series 1000-1500 8 compression-shear 8-12
6126 series 1400-2000 8-10 mounts 7-11

The sourcing guide explains the data required for the selection, and the cylinder block guide covers the engine structure that the mounts support.

Installation and Levelling

The installation of the mounts is simple but must be done correctly. The engine is lifted, the mounts are placed on the frame at the marked positions, and the engine is lowered onto the mounts. The fixing bolts are inserted, the mounts are checked for the correct seating, and the bolts are torqued to the specified value. The set is then levelled using the shims and the adjusting nuts, and the alignment of the engine and the alternator is verified with the dial gauge or the laser.

The levelling is critical for two reasons. First, the engine and the alternator must be aligned within the coupling tolerance, and a misalignment caused by the uneven mounts loads the coupling and the bearings. Second, the mounts must share the load evenly: if one mount is higher, it takes a larger share of the weight and deflects more, and the isolation of that corner is different from the others. The frame is checked for the flatness, and the mounts are selected with a matched height where the application requires.

The pipework and the electrical connections to the engine are made with a flexible section: the exhaust bellows, the flexible fuel hoses, and the flexible electrical conduits allow the engine to move on its mounts without stressing the connections. A rigid connection to a mounted engine defeats the isolation and transmits the vibration through the pipe. The anti-vibration mount is also used under the radiator, the battery tray, and the control panel, with the same principles. The installation guide covers the complete sequence, and the exhaust manifold guide covers the flexible exhaust connection.

Inspection and Replacement

The mounts wear and degrade over time, and the condition is checked during the scheduled maintenance. The signs of a failed mount are: the engine sits lower than the original height, the vibration and the noise transmitted to the frame increase, the rubber is cracked, swollen, or separated from the plate, the mount is soaked in oil, or the engine moves visibly when the load is applied. A failed mount is replaced as a set, because the remaining mounts have the same age and the mixed stiffness distorts the isolation.

The replacement procedure is straightforward: the engine is supported with the jack or the crane, the fixing bolts are removed, the old mounts are lifted out, and the new mounts are fitted at the correct height. The bolts are torqued to the specification, the set is levelled, and the alignment is re-checked. The new mounts are inspected after the first run, and the settling is expected in the first hours: the engine height may drop slightly as the rubber takes the set, and the torque of the bolts is checked and re-tightened.

The service life of the mount depends on the duty, the temperature, and the oil exposure. A mount in a clean, dry, cool location lasts 5 to 10 years; a mount exposed to the oil mist, the heat, and the ozone degrades in 2 to 3 years. The genuine mounts are manufactured with the correct rubber compound and the bond quality, and the aftermarket mounts must be verified for the load rating, the deflection, and the height. The maintenance schedule guide covers the inspection intervals, and the after-sales guide covers the spares support.

Applications on the Common Engine Families

The anti-vibration mount is a standard consumable on the Chinese 6105, 6113, 4100, 4105, and 6126 generator engines, and the replacement mounts are matched by the engine model and the set configuration. The mount part is identified by the engine model, the position (front or rear, left or right), the height, and the fixing dimensions. The same engine family may use different mounts in the different set configurations, because the alternator weight and the frame design change the load distribution.

On the Cummins, Perkins, Weichai, and Yuchai sets, the mounts are supplied by the set builder or the engine manufacturer, and the replacement is made with the original or the verified equivalent. The buyer should provide the engine model, the set builder, the serial number if available, and a photo or the dimensions of the existing mount, and the supplier confirms the correct replacement. The complete set of the mounts is recommended, together with the shims and the bolts where the old hardware is worn or corroded.

The order information for the mounts includes the engine model, the quantity, the height, and the fixing dimensions. The genuine and the verified aftermarket mounts are available, and the quality is confirmed by the load rating and the rubber compound. The Cummins and Perkins cross-reference guide covers the interchange data, and the drive belt guide covers the belt-driven accessories whose tension is affected by the mount deflection.

Vibration Analysis and Mount Placement

The vibration analysis is the first step in the mount selection and the placement. The dominant frequencies of the engine and the driven equipment are identified at the idle, the rated, and the transient conditions, and the critical orders are compared with the resonance frequencies of the mounting system. The mount stiffness and the damping are selected so that the natural frequency of the suspended system is below the disturbing frequency, typically by a margin of 30 to 50 percent, and the amplification at the resonance is avoided. The static and the dynamic loads at each mount point are calculated from the weight distribution and the torque reaction, and the mounts are rated for the combined load.

The placement of the mounts follows the frame design and the load distribution: the mounts are positioned near the corners of the frame, the centre of gravity is located, and the mount spacing is arranged so that the deflection is uniform under the load. The levelling and the alignment are part of the placement: the frame is levelled, the mounts are compressed evenly, and the driven equipment is aligned with the engine. The mounts are installed with the correct torque and the washers, and the travel is checked against the limit stops. The placement is verified by the vibration survey, and the readings are compared with the acceptance levels. The installation guide covers the frame work, and the fan shroud guide covers the related cooling fit.

Mount Inspection and Replacement Intervals

The anti-vibration mounts are inspected at the maintenance intervals: the rubber is checked for the cracking, the swelling, and the separation, the metal parts are checked for the corrosion and the damage, and the bolting is checked for the torque. The sag of the mount is measured, and the excessive sag indicates the rubber softening or the overload. The mounts are inspected more frequently in the hot, the oily, and the chemically aggressive environments, because the rubber degrades faster. The inspection record notes the condition and the readings, and the mounts are scheduled for the replacement when the deterioration is significant.

The replacement interval is based on the operating hours and the condition, typically 20,000 to 40,000 hours for the quality rubber mounts in the normal service, and shorter in the severe conditions. The mounts are replaced as a set to keep the even deflection, and the new mounts are the same type and the rating. The replacement is performed with the frame supported, and the bolts are torqued to the specification. After the replacement, the frame is re-levelled and the alignment is checked, and the vibration is surveyed to verify the improvement. The maintenance schedule guide covers the intervals, and the troubleshooting guide covers the diagnosis.

Frequently Asked Questions

Q1: What is a generator anti-vibration mount?
It is a rubber-metal element that supports the engine and isolates its vibration from the frame and the building by elastic deflection.
Q2: How many mounts does a generator set need?
Typically four to eight, depending on the engine size and the weight distribution; the set builder specifies the number and the positions.
Q3: How is the mount selected?
From the static load per mount, the firing frequency of the engine, and the required isolation, with a frequency ratio of at least 2.5.
Q4: When should the mounts be replaced?
When the rubber is cracked or separated, the engine sits low, the transmitted vibration increases, or the mount is oil-soaked and degraded.
Q5: Why must the mounts be replaced as a set?
Because mixed old and new mounts have different stiffness and height, which distorts the isolation and overloads the stiffer mounts.
Q6: What is the service life of a mount?
About 5 to 10 years in a clean, dry location; 2 to 3 years when exposed to oil, heat, and ozone.
Q7: What happens if a mount fails?
The engine drops, the vibration and noise increase, the flexible connections and the coupling are stressed, and the engine can move under load.
Q8: What information do I need to order mounts?
The engine model, the quantity, the position, the height, and the fixing dimensions, or a photo of the existing mount.
Q9: Can I use a generic mount instead of the original?
Only if the load rating, the deflection, the height, and the fixing dimensions are verified against the original specification.

Need anti-vibration mounts for your generator engine?

Contact us with the engine model and the mount details for the correct replacement set, with verified quality and fast shipping.

Email sales@huaquanpower.net